Displacement from – to 6.23 - 11.15 cm³ and cover a cooling capacity (ASHRAE) range of:
Varianten für FR8.5G | Variante 1 | Variante 2 | |
---|---|---|---|
Bestellnummer | 103G6780 | 103G6790 | |
Typenbezeichnung | FR8.5G | FR8.5G | |
Produkt Status | Produktion - aktiv | Produktion - Variante | |
Leistung | Check Performance | Check Performance | |
Datenblatt | Download | Download | |
3D Modell | |||
Stromversorgung | 220-240V/50Hz | Yes | Yes |
110-115V/50Hz | No | No | |
115-127V/60Hz | No | No | |
208-230V/60Hz | Yes | Yes | |
12-24V DC | No | No | |
48V DC | No | No | |
Kältemittel | R170 | No | No |
R1270 | No | No | |
R134a | Yes | Yes | |
R513A | Yes | No | |
R1234yf | No | No | |
R290 | No | No | |
R404A | No | No | |
R452A | No | No | |
R407C | No | No | |
R600a | No | No | |
Anwendungen | LBP | Yes | Yes |
MBP | Yes | Yes | |
HBP | Yes | Yes | |
ULT | No | No | |
Motoren | RSIR | Yes | Yes |
RSCR | No | No | |
CSIR | Yes | Yes | |
CSCR | No | No | |
DC/PM | No | No | |
Pre-assembled start equipment | No | No | |
Abmessungen | Höhe [mm | in.] | 196 | 7.72 | 196 | 7.72 |
Gewicht [kg | lbs.] | 10.6 | 23.4 | 10.6 | 23.4 | |
Druckstutzen ⌀ [mm | in.] | 6.2 | 0.24 | 6.2 | 0.24 | Material Druckstutzen | Cu-plated steel | Cu-plated steel |
Füllstutzen ⌀ [mm | in.] | 6.2 | 0.24 | 6.2 | 0.24 | |
Material Füllstutzen | Cu-plated steel | Cu-plated steel | |
Saugstutzen ⌀ [mm | in.] | 8.2 | 0.32 | 8.2 | 0.32 | |
Material Saugstutzen | Cu-plated steel | Cu-plated steel | |
Design | Verdunstungsschalenhalter | ||
Hubraum [cm³ | cu.in.] | 7.95 | 0.49 | 7.95 | 0.49 | |
Ölfüllmenge [cm³ | fl.oz.] | 450 | 15.22 | 450 | 15.22 | |
Ölsorte | POE | POE|OC | |
Leistung | Motordrehzahl [UpM] | 2900 | 2900 |
ULT Cooling capacity [W | Btu/h] | 0 | 0 | 0 | 0 | |
ULT COP [W/W | Btu/Wh] | 0 | 0 | 0 | 0 | |
LBP Kälteleistung [W | Btu/h] | 172 | 587 | 172 | 587 | |
LBP COP [W/W | Btu/Wh] | 1.08 | 3.7 | 1.08 | 3.7 | |
MBP Kälteleistung [W | Btu/h] | 388 | 1324 | 388 | 1324 | |
MBP COP [W/W | Btu/Wh] | 1.57 | 5.4 | 1.57 | 5.4 | |
HBP Kälteleistung [W | Btu/h] | 714 | 2438 | 714 | 2438 | |
HBP COP [W/W | Btu/Wh] | 2.17 | 7.4 | 2.17 | 7.4 | |
Zulassungen | CCC | Yes | Yes |
EAC | Yes | No | |
EN 60335-2-34 with Annex AA | No | No | |
EN 60335-2-34 | Yes | Yes | |
UL | Yes | Yes | |
E4 72/245 95/54 0277 00 | No | No | |
IEC 60335-1 & IEC 60335-2-34 | No | No | |
Inmetro | No | No | |
E4 72/245 95/54 0211 37 | No | No | |
CB - IEC 60335-2-34 | No | No | |
KC | No | No |