Displacement from – to 4 - 8.6 cm³ and cover a cooling capacity (ASHRAE) range of:
Varianten für KLF7.7CNDS | Variante 1 | |
---|---|---|
Bestellnummer | 106H2803 | |
Typenbezeichnung | KLF7.7CNDS | |
Produkt Status | Produktion - aktiv | |
Leistung | Check Performance | |
Datenblatt | Download | |
3D Modell | Download | |
Stromversorgung | 220-240V/50Hz | Yes |
110-115V/50Hz | No | |
115-127V/60Hz | No | |
208-230V/60Hz | No | |
12-24V DC | No | |
48V DC | No | |
Kältemittel | R170 | No |
R1270 | No | |
R134a | No | |
R513A | No | |
R1234yf | No | |
R290 | Yes | |
R404A | No | |
R452A | No | |
R407C | No | |
R600a | No | |
Anwendungen | LBP | Yes |
MBP | Yes | |
HBP | No | |
ULT | No | |
Motoren | RSIR | No |
RSCR | No | |
CSIR | Yes | |
CSCR | No | |
DC/PM | No | |
Pre-assembled start equipment | No | |
Abmessungen | Höhe [mm | in.] | 181.7 | 7.15 |
Gewicht [kg | lbs.] | 9.6 | 21.2 | |
Druckstutzen ⌀ [mm | in.] | 6.2 | 0.24 | Material Druckstutzen | Copper |
Füllstutzen ⌀ [mm | in.] | 6.2 | 0.24 | |
Material Füllstutzen | Copper | |
Saugstutzen ⌀ [mm | in.] | 8.2 | 0.32 | |
Material Saugstutzen | Copper | |
Design | Verdunstungsschalenhalter | |
Hubraum [cm³ | cu.in.] | 7.7 | 0.47 | |
Ölfüllmenge [cm³ | fl.oz.] | 170 | 5.75 | |
Ölsorte | POE | |
Leistung | Motordrehzahl [UpM] | 2900 |
ULT Cooling capacity [W | Btu/h] | 0 | 0 | |
ULT COP [W/W | Btu/Wh] | 0 | 0 | |
LBP Kälteleistung [W | Btu/h] | 372 | 1269 | |
LBP COP [W/W | Btu/Wh] | 1.48 | 5.1 | |
MBP Kälteleistung [W | Btu/h] | 660 | 2253 | |
MBP COP [W/W | Btu/Wh] | 1.97 | 6.7 | |
HBP Kälteleistung [W | Btu/h] | 0 | 0 | |
HBP COP [W/W | Btu/Wh] | 0 | 0 | |
Zulassungen | CCC | Yes |
EAC | No | |
EN 60335-2-34 with Annex AA | No | |
EN 60335-2-34 | Yes | |
UL | No | |
E4 72/245 95/54 0277 00 | No | |
IEC 60335-1 & IEC 60335-2-34 | No | |
Inmetro | No | |
E4 72/245 95/54 0211 37 | No | |
CB - IEC 60335-2-34 | No | |
KC | No |