Displacement from – to 2 - 3 cm³ and cover a cooling capacity (ASHRAE) range of:
Variantes para MP2UVULTM | Variante 1 | |
---|---|---|
Código | 101M0800 | |
Designación de tipo | MP2UVULTM | |
Estado del producto | Producción - Activa | |
Rendimiento | Check Performance | |
Ficha técnica | Descargar | |
Modelo 3D | ||
Fuente de alimentación | 220-240V/50Hz | No |
110-115V/50Hz | No | |
115-127V/60Hz | No | |
208-230V/60Hz | No | |
12-24V DC | Yes | |
48V DC | No | |
Refrigerantes | R170 | Yes |
R1270 | No | |
R134a | No | |
R513A | No | |
R1234yf | No | |
R290 | No | |
R404A | No | |
R452A | No | |
R407C | No | |
R600a | No | |
Aplicaciones | LBP | No |
MBP | No | |
HBP | No | |
ULT | Yes | |
Motores | RSIR | No |
RSCR | No | |
CSIR | No | |
CSCR | No | |
DC/PM | Yes | |
Partes eléctricas pre-montadas | No | |
Dimensiones | Altura [mm | in.] | 137 | 5.39 |
Peso [kg | lbs.] | 4.3 | 9.5 | |
Tubo de compresión [mm | in.] | 5 | 0.2 | Material de descarga | Cu-plated steel |
Tubo de carga [mm | in.] | 6.2 | 0.24 | |
Material de proceso | Cu-plated steel | |
Tubo de aspiración [mm | in.] | 6.2 | 0.24 | |
Material de aspiración | Cu-plated steel | |
Diseño | Accesorio bandeja de evaporación | |
Cubicaje [cm³ | cu.in.] | 2 | 0.12 | |
Carga de aceite [cm³ | fl.oz.] | 150 | 5.07 | |
Tipo de aceite | POE | |
Rendimiento | Velocidad del motor [rpm] | 2500 |
ULT Cooling capacity [W | Btu/h] | 27 | 92 | |
ULT COP [W/W | Btu/Wh] | 1.39 | 4.7 | |
LBP Producción frigorífica [W | Bth/h] | 0 | 0 | |
LBP COP [W/W | Btu/Wh] | 0 | 0 | |
MBP Producción frigoríficay [W | Bth/h] | 0 | 0 | |
MBP COP [W/W | Btu/Wh] | 0 | 0 | |
HBP Producción frigorífica [W | Bth/h] | 0 | 0 | |
HBP COP [W/W | Btu/Wh] | 0 | 0 | |
Homologaciones | CCC | No |
EAC | No | |
EN 60335-2-34 with Annex AA | No | |
EN 60335-2-34 | No | |
UL | Yes | |
E4 72/245 95/54 0277 00 | No | |
IEC 60335-1 & IEC 60335-2-34 | No | |
Inmetro | No | |
E4 72/245 95/54 0211 37 | No | |
CB - IEC 60335-2-34 | No | |
KC | No |