Last Update
03.02.2025

Product Details for PL30F

  • Secop P-Series Compressors are available in:

    Displacement from – to 1.41 - 2.5 cm³ and cover a cooling capacity (ASHRAE) range of:

    • LBP: 25–59 W
    • MBP: 66–126 W
    • HBP: 130–192 W
    Sales Request Technical Support
Variants for PL30F variant 1
Code number 101G9100
Type designation PL30F
Product status 製造中
Performance Check Performance
Data Sheet Download
3D Model
Power supply 220-240V/50Hz No
110-115V/50Hz Yes
115-127V/60Hz Yes
208-230V/60Hz No
12-24V DC No
48V DC No
Refrigerants R170 No
R1270 No
R134a Yes
R513A No
R1234yf No
R290 No
R404A No
R452A No
R407C No
R600a No
Applications LBP Yes
MBP Yes
HBP Yes
ULT No
Motors RSIR Yes
RSCR No
CSIR Yes
CSCR No
DC/PM No
Pre-assembled start equipment No
Dimensions Height [mm | in.] 134 | 5.28
Weight [kg | lbs.] 4.3 | 9.5
Discharge connector ⌀ [mm | in.] 5 | 0.2
Discharge Material Cu-plated steel
Process connector ⌀ [mm | in.] 6.5 | 0.26
Process Material Cu-plated steel
Suction connector ⌀ [mm | in.] 6.5 | 0.26
Suction Material Cu-plated steel
Design Evap. tray fixture
Displacement [cm³ | cu.in.] 1.41 | 0.09
Oil Charge [cm³ | fl.oz.] 150 | 5.07
Oil Type POE
Performance Motor Speed [rpm] 3500
ULT Cooling capacity [W | Btu/h] 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0
LBP Cooling capacity [W | Btu/h] 30 | 103
LBP COP [W/W | Btu/Wh] 0.6 | 2
MBP Cooling capacity [W | Btu/h] 79 | 268
MBP COP [W/W | Btu/Wh] 1.2 | 4.1
HBP Cooling capacity [W | Btu/h] 152 | 518
HBP COP [W/W | Btu/Wh] 1.89 | 6.5
Approvals CCC No
EAC Yes
EN 60335-2-34 with Annex AA No
EN 60335-2-34 No
UL Yes
E4 72/245 95/54 0277 00 No
IEC 60335-1 & IEC 60335-2-34 No
Inmetro No
E4 72/245 95/54 0211 37 No
CB - IEC 60335-2-34 No
KC No