Last Update
03.02.2025

Product Details for NL7CLX

  • Secop N-Series Compressors are available in:

    Displacement from – to 6.13 - 14.65 cm³ and cover a cooling capacity (ASHRAE) range of:

    • LBP: 127–766 W
    • MBP: 320–1359 W
    • HBP: 1122–1211 W
    Sales Request Technical Support
Variants for NL7CLX variant 1 variant 2 variant 3
Code number 105F3710 105F3712 105F3713
Type designation NL7CLX NL7CLX NL7CLX
Product status 製造中 同系統品を製造中 同系統品を製造中
Performance Check Performance Check Performance Check Performance
Data Sheet Download Download Download
3D Model Download
Power supply 220-240V/50Hz Yes Yes Yes
110-115V/50Hz No No No
115-127V/60Hz No No No
208-230V/60Hz No No No
12-24V DC No No No
48V DC No No No
Refrigerants R170 No No No
R1270 No No No
R134a No No No
R513A No No No
R1234yf No No No
R290 No No No
R404A Yes Yes Yes
R452A Yes No No
R407C No No No
R600a No No No
Applications LBP Yes Yes Yes
MBP No No No
HBP No No No
ULT No No No
Motors RSIR No No No
RSCR No No No
CSIR Yes Yes Yes
CSCR No No No
DC/PM No No No
Pre-assembled start equipment No No No
Dimensions Height [mm | in.] 203 | 7.99 203 | 7.99 203 | 7.99
Weight [kg | lbs.] 10.4 | 22.9 10.4 | 22.9 10.4 | 22.9
Discharge connector ⌀ [mm | in.] 6.2 | 0.24 6.5 | 0.26 6.2 | 0.24
Discharge Material Copper Copper Copper
Process connector ⌀ [mm | in.] 6.2 | 0.24 6.5 | 0.26 6.2 | 0.24
Process Material Copper Copper Copper
Suction connector ⌀ [mm | in.] 8.2 | 0.32 8.2 | 0.32 8.2 | 0.32
Suction Material Copper Copper Copper
Design Evap. tray fixture
Displacement [cm³ | cu.in.] 7.27 | 0.44 7.27 | 0.44 7.27 | 0.44
Oil Charge [cm³ | fl.oz.] 300 | 10.14 300 | 10.14 300 | 10.14
Oil Type POE POE POE
Performance Motor Speed [rpm] 2900 2900 2900
ULT Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0
LBP Cooling capacity [W | Btu/h] 388 | 1326 388 | 1326 388 | 1326
LBP COP [W/W | Btu/Wh] 1.31 | 4.5 1.31 | 4.5 1.31 | 4.5
MBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0
MBP COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0
HBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0
HBP COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0
Approvals CCC Yes Yes Yes
EAC Yes No Yes
EN 60335-2-34 with Annex AA No No No
EN 60335-2-34 Yes Yes Yes
UL No Yes Yes
E4 72/245 95/54 0277 00 No No No
IEC 60335-1 & IEC 60335-2-34 No No No
Inmetro No No No
E4 72/245 95/54 0211 37 No No No
CB - IEC 60335-2-34 No No No
KC No No No