Last Update
03.02.2025

Product Details for NL7CN

  • Secop N-Series Compressors are available in:

    Displacement from – to 6.13 - 14.65 cm³ and cover a cooling capacity (ASHRAE) range of:

    • LBP: 127–766 W
    • MBP: 320–1359 W
    • HBP: 1122–1211 W
    Sales Request Technical Support
Variants for NL7CN variant 1
Code number 105H6756
Type designation NL7CN
Product status 製造中
Performance Check Performance
Data Sheet Download
3D Model Download
Power supply 220-240V/50Hz Yes
110-115V/50Hz No
115-127V/60Hz No
208-230V/60Hz No
12-24V DC No
48V DC No
Refrigerants R170 No
R1270 No
R134a No
R513A No
R1234yf No
R290 Yes
R404A No
R452A No
R407C No
R600a No
Applications LBP Yes
MBP Yes
HBP No
ULT No
Motors RSIR Yes
RSCR Yes
CSIR Yes
CSCR No
DC/PM No
Pre-assembled start equipment No
Dimensions Height [mm | in.] 203 | 7.99
Weight [kg | lbs.] 10.5 | 23.1
Discharge connector ⌀ [mm | in.] 6.2 | 0.24
Discharge Material Copper
Process connector ⌀ [mm | in.] 6.2 | 0.24
Process Material Copper
Suction connector ⌀ [mm | in.] 8.2 | 0.32
Suction Material Copper
Design Evap. tray fixture
Displacement [cm³ | cu.in.] 7.27 | 0.44
Oil Charge [cm³ | fl.oz.] 270 | 9.13
Oil Type POE
Performance Motor Speed [rpm] 2900
ULT Cooling capacity [W | Btu/h] 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0
LBP Cooling capacity [W | Btu/h] 325 | 1110
LBP COP [W/W | Btu/Wh] 1.35 | 4.6
MBP Cooling capacity [W | Btu/h] 594 | 2030
MBP COP [W/W | Btu/Wh] 1.82 | 6.2
HBP Cooling capacity [W | Btu/h] 0 | 0
HBP COP [W/W | Btu/Wh] 0 | 0
Approvals CCC Yes
EAC Yes
EN 60335-2-34 with Annex AA Yes
EN 60335-2-34 No
UL No
E4 72/245 95/54 0277 00 No
IEC 60335-1 & IEC 60335-2-34 No
Inmetro No
E4 72/245 95/54 0211 37 No
CB - IEC 60335-2-34 Yes
KC No