Last Update
03.02.2025
Configuration-Code NLU11KK


Code number 105H6132 105H6198
Type designation NLU11KK.1 NLU11KK.1
Product status 同系統品を製造中 製造中
Data Sheet Download Download
Setup
Polynomial NLU11KK
Voltage range [V … V] 198 … 254
Frequency 50
High starting torque no
Run capacitor yes
Motor speed [rpm] 2900
Variable speed no
Refrigerant R600a
Specials Tropical use recommended no
Heavy duty pull down capability no
Mobile operation possible no
Hot gas defrost capability no
Cooling Required cooling Max. ambient temp.: 43°C S (static cooling)
Operation limits diagram = short = continuous
CECOMAF CECOMAF ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 149 | 509 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.55 | 5.3 n/a | n/a n/a | n/a
ASHRAE ASHRAE ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 199 | 680 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.97 | 6.7 n/a | n/a n/a | n/a
EN12900 EN12900 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 105 | 359 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.59 | 5.4 n/a | n/a n/a | n/a
ARI540 ARI540 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 163 | 557 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.66 | 5.7 n/a | n/a n/a | n/a
AHAM AHAM ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 215 | 734 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 2.32 | 7.9 n/a | n/a n/a | n/a
VSD_opt1 VSD_opt1 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 199 | 680 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 2.32 | 7.9 n/a | n/a n/a | n/a
VSD_opt2 VSD_opt2 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 182 | 622 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 2.03 | 6.9 n/a | n/a n/a | n/a
lowTemp lowTemp ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a n/a | n/a n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a n/a | n/a n/a | n/a n/a | n/a