Last Update
03.02.2025
Configuration-Code SC18Gtwin25


Code number 104G8880
Type designation SC18/18G
Product status 製造中
Data Sheet Download
Setup
Polynomial SC18Gtwin25
Voltage range [V … V] 187 … 254
Frequency 50
High starting torque yes
Run capacitor no
Motor speed [rpm] 2900
Variable speed no
Refrigerant R134a
Specials Tropical use recommended yes
Heavy duty pull down capability yes
Mobile operation possible no
Hot gas defrost capability yes
Cooling Required cooling Max. ambient temp.: 43°C F2 (fan 3m/s)
Operation limits diagram = short = continuous
CECOMAF CECOMAF ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 566 | 1933 1369 | 4675 2674 | 9132
COP | EER [W/W | Btu/Wh] n/a | n/a 0.86 | 2.9 1.35 | 4.6 1.92 | 6.6
ASHRAE ASHRAE ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 781 | 2667 1776 | 6065 3228 | 11024
COP | EER [W/W | Btu/Wh] n/a | n/a 1.12 | 3.8 1.63 | 5.6 2.24 | 7.6
EN12900 EN12900 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 313 | 1069 1527 | 5215 2697 | 9210
COP | EER [W/W | Btu/Wh] n/a | n/a 0.74 | 2.5 1.63 | 5.6 2.04 | 7
ARI540 ARI540 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 631 | 2155 1657 | 5659 2770 | 9460
COP | EER [W/W | Btu/Wh] n/a | n/a 0.94 | 3.2 1.6 | 5.5 1.92 | 6.6
AHAM AHAM ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 897 | 3063 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.37 | 4.7 n/a | n/a n/a | n/a
VSD_opt1 VSD_opt1 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 845 | 2886 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.34 | 4.6 n/a | n/a n/a | n/a
VSD_opt2 VSD_opt2 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 725 | 2476 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.17 | 4 n/a | n/a n/a | n/a
lowTemp lowTemp ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a n/a | n/a n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a n/a | n/a n/a | n/a n/a | n/a