Last Update
03.02.2025
Configuration-Code TL4CNX2_16


Code number 102H3490
Type designation TL4CNX.2
Product status 製造中
Data Sheet Download
Setup
Polynomial TL4CNX2_16
Voltage range [V … V] 95 … 135
Frequency 60
High starting torque yes
Run capacitor no
Motor speed [rpm] 3500
Variable speed no
Refrigerant R290
Specials Tropical use recommended yes
Heavy duty pull down capability yes
Mobile operation possible no
Hot gas defrost capability no
Cooling Required cooling Max. ambient temp.: 43°C F2 (fan 3m/s)
Operation limits diagram = short = continuous
CECOMAF CECOMAF ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 157 | 536 309 | 1055 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 0.97 | 3.3 1.47 | 5 n/a | n/a
ASHRAE ASHRAE ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 211 | 721 391 | 1335 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.26 | 4.3 1.79 | 6.1 n/a | n/a
EN12900 EN12900 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 120 | 410 345 | 1178 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 0.91 | 3.1 1.78 | 6.1 n/a | n/a
ARI540 ARI540 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 173 | 591 369 | 1260 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.05 | 3.6 1.77 | 6 n/a | n/a
AHAM AHAM ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 229 | 782 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.45 | 5 n/a | n/a n/a | n/a
VSD_opt1 VSD_opt1 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 212 | 724 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.4 | 4.8 n/a | n/a n/a | n/a
VSD_opt2 VSD_opt2 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 195 | 666 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.26 | 4.3 n/a | n/a n/a | n/a
lowTemp lowTemp ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a n/a | n/a n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a n/a | n/a n/a | n/a n/a | n/a