Displacement from – to 2 - 3 cm³ and cover a cooling capacity (ASHRAE) range of:
Variants for BD250GH.2 | variant 1 | variant 2 | |
---|---|---|---|
Code number | 101Z0405 | 101Z0406 | |
Type designation | BD250GH.2 | BD250GH.2 | |
Product status | Production - Active | Production - Active | |
Performance | Check Performance | Check Performance | |
Data Sheet | Download | Download | |
3D Model | Download | Download | |
Power supply | 220-240V/50Hz | No | No |
110-115V/50Hz | No | No | |
115-127V/60Hz | No | No | |
208-230V/60Hz | No | No | |
12-24V DC | No | Yes | |
48V DC | Yes | No | |
Refrigerants | R170 | No | No |
R1270 | No | No | |
R134a | Yes | Yes | |
R513A | No | No | |
R1234yf | No | No | |
R290 | No | No | |
R404A | No | No | |
R452A | No | No | |
R407C | No | No | |
R600a | No | No | |
Applications | LBP | Yes | Yes |
MBP | Yes | Yes | |
HBP | Yes | Yes | |
ULT | No | No | |
Motors | RSIR | No | No |
RSCR | No | No | |
CSIR | No | No | |
CSCR | No | No | |
DC/PM | Yes | Yes | |
Pre-assembled start equipment | No | No | |
Dimensions | Height [mm | in.] | 137 | 5.39 | 137 | 5.39 |
Weight [kg | lbs.] | 4.4 | 9.7 | 4.4 | 9.7 | |
Discharge connector ⌀ [mm | in.] | 5 | 0.2 | 5 | 0.2 | Discharge Material | Cu-plated steel | Cu-plated steel |
Process connector ⌀ [mm | in.] | 6.2 | 0.24 | 6.2 | 0.24 | |
Process Material | Cu-plated steel | Cu-plated steel | |
Suction connector ⌀ [mm | in.] | 6.2 | 0.24 | 6.2 | 0.24 | |
Suction Material | Cu-plated steel | Cu-plated steel | |
Design | Evap. tray fixture | ||
Displacement [cm³ | cu.in.] | 2.5 | 0.15 | 2.5 | 0.15 | |
Oil Charge [cm³ | fl.oz.] | 150 | 5.07 | 150 | 5.07 | |
Oil Type | POE | POE | |
Performance | Motor Speed [rpm] | 2500 | 2500 |
ULT Cooling capacity [W | Btu/h] | 0 | 0 | 0 | 0 | |
ULT COP [W/W | Btu/Wh] | 0 | 0 | 0 | 0 | |
LBP Cooling capacity [W | Btu/h] | 50 | 172 | 46 | 156 | |
LBP COP [W/W | Btu/Wh] | 1.14 | 3.9 | 1.07 | 3.7 | |
MBP Cooling capacity [W | Btu/h] | 111 | 380 | 112 | 384 | |
MBP COP [W/W | Btu/Wh] | 1.68 | 5.7 | 1.95 | 6.7 | |
HBP Cooling capacity [W | Btu/h] | 215 | 735 | 214 | 732 | |
HBP COP [W/W | Btu/Wh] | 2.64 | 9 | 2.81 | 9.6 | |
Approvals | CCC | No | No |
EAC | Yes | Yes | |
EN 60335-2-34 with Annex AA | No | No | |
EN 60335-2-34 | No | No | |
UL | Yes | No | |
E4 72/245 95/54 0277 00 | No | No | |
IEC 60335-1 & IEC 60335-2-34 | No | No | |
Inmetro | No | No | |
E4 72/245 95/54 0211 37 | No | Yes | |
CB - IEC 60335-2-34 | No | No | |
KC | No | No |