Last Update
03.02.2025

Product Details for TLES4.8KK.3

  • Secop T-Series Compressors are available in:

    Displacement from – to 2.6 - 10.13 cm³ and cover a cooling capacity (ASHRAE) range of:

    • LBP: 45–272 W
    • MBP: 11–392 W
    • HBP: 218–488 W
    Sales Request Technical Support
Variants for TLES4.8KK.3 variant 1 variant 2 variant 3 variant 4
Code number 102H4579 102H4596 102H4538 102H4598
Type designation TLES4.8KK.3 TLES4.8KK.3 TLES4.8KK.3 TLES4.8KK.3
Product status Production - Active Production - Active Production - Variant Production - Variant
Performance Check Performance Check Performance Check Performance Check Performance
Data Sheet Download Download
3D Model Download
Power supply 220-240V/50Hz Yes Yes Yes Yes
110-115V/50Hz No No No No
115-127V/60Hz No No No No
208-230V/60Hz No No No No
12-24V DC No No No No
48V DC No No No No
Refrigerants R170 No No No No
R1270 No No No No
R134a No No No No
R513A No No No No
R1234yf No No No No
R290 No No No No
R404A No No No No
R452A No No No No
R407C No No No No
R600a Yes Yes Yes Yes
Applications LBP Yes Yes Yes Yes
MBP No No No No
HBP No No No No
ULT No No No No
Motors RSIR Yes Yes Yes Yes
RSCR Yes Yes Yes Yes
CSIR No No No No
CSCR No No No No
DC/PM No No No No
Pre-assembled start equipment No No No No
Dimensions Height [mm | in.] 163 | 6.42 163 | 6.42 163 | 6.42 163 | 6.42
Weight [kg | lbs.] 6.4 | 14.1 6.4 | 14.1 6.4 | 14.1 6.4 | 14.1
Discharge connector ⌀ [mm | in.] 5 | 0.2 5 | 0.2 5 | 0.2 5 | 0.2
Discharge Material Copper Copper Cu-plated steel Cu-plated steel
Process connector ⌀ [mm | in.] 6.2 | 0.24 4.5 | 0.18 6.2 | 0.24 6.2 | 0.24
Process Material Copper Copper Cu-plated steel Cu-plated steel
Suction connector ⌀ [mm | in.] 6.2 | 0.24 6.2 | 0.24 6.2 | 0.24 6.2 | 0.24
Suction Material Copper Copper Cu-plated steel Cu-plated steel
Design Evap. tray fixture
Displacement [cm³ | cu.in.] 4.78 | 0.29 4.78 | 0.29 4.78 | 0.29 4.78 | 0.29
Oil Charge [cm³ | fl.oz.] 180 | 6.09 180 | 6.09 180 | 6.09 180 | 6.09
Oil Type Mineral Mineral Mineral Mineral
Performance Motor Speed [rpm] 2900 2900 2900 2900
ULT Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0 0 | 0
LBP Cooling capacity [W | Btu/h] 74 | 253 74 | 253 74 | 253 74 | 253
LBP COP [W/W | Btu/Wh] 1.3 | 4.4 1.3 | 4.4 1.3 | 4.4 1.3 | 4.4
MBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0 0 | 0
MBP COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0 0 | 0
HBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0 0 | 0
HBP COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0 0 | 0
Approvals CCC No No No No
EAC Yes No Yes Yes
EN 60335-2-34 with Annex AA Yes Yes Yes Yes
EN 60335-2-34 No No No No
UL No No No No
E4 72/245 95/54 0277 00 No No No No
IEC 60335-1 & IEC 60335-2-34 No No No No
Inmetro No No No No
E4 72/245 95/54 0211 37 No No No No
CB - IEC 60335-2-34 No No No No
KC No No No No