Displacement from – to 2.6 - 10.13 cm³ and cover a cooling capacity (ASHRAE) range of:
Variants for TLES5.7KK.3 | variant 1 | variant 2 | variant 3 | |
---|---|---|---|---|
Code number | 102H4694 | 102H4638 | 102H4676 | |
Type designation | TLES5.7KK.3 | TLES5.7KK.3 | TLES5.7KK.3 | |
Product status | Production - Active | Production - Variant | Production - Variant | |
Performance | Check Performance | Check Performance | Check Performance | |
Data Sheet | Download | Download | ||
3D Model | Download | |||
Power supply | 220-240V/50Hz | Yes | Yes | Yes |
110-115V/50Hz | No | No | No | |
115-127V/60Hz | No | No | No | |
208-230V/60Hz | No | No | No | |
12-24V DC | No | No | No | |
48V DC | No | No | No | |
Refrigerants | R170 | No | No | No |
R1270 | No | No | No | |
R134a | No | No | No | |
R513A | No | No | No | |
R1234yf | No | No | No | |
R290 | No | No | No | |
R404A | No | No | No | |
R452A | No | No | No | |
R407C | No | No | No | |
R600a | Yes | Yes | Yes | |
Applications | LBP | Yes | Yes | Yes |
MBP | No | No | No | |
HBP | No | No | No | |
ULT | No | No | No | |
Motors | RSIR | Yes | Yes | Yes |
RSCR | Yes | Yes | Yes | |
CSIR | No | No | No | |
CSCR | No | No | No | |
DC/PM | No | No | No | |
Pre-assembled start equipment | No | No | No | |
Dimensions | Height [mm | in.] | 163 | 6.42 | 163 | 6.42 | 163 | 6.42 |
Weight [kg | lbs.] | 6.4 | 14.1 | 6.4 | 14.1 | 6.4 | 14.1 | |
Discharge connector ⌀ [mm | in.] | 5 | 0.2 | 5 | 0.2 | 4.9 | 0.19 | Discharge Material | Copper | Cu-plated steel | Copper |
Process connector ⌀ [mm | in.] | 6.2 | 0.24 | 6.2 | 0.24 | 4.5 | 0.18 | |
Process Material | Copper | Cu-plated steel | Copper | |
Suction connector ⌀ [mm | in.] | 6.2 | 0.24 | 6.2 | 0.24 | 6.2 | 0.24 | |
Suction Material | Copper | Cu-plated steel | Copper | |
Design | Evap. tray fixture | |||
Displacement [cm³ | cu.in.] | 5.7 | 0.35 | 5.7 | 0.35 | 5.7 | 0.35 | |
Oil Charge [cm³ | fl.oz.] | 180 | 6.09 | 180 | 6.09 | 180 | 6.09 | |
Oil Type | Mineral | Mineral | Mineral | |
Performance | Motor Speed [rpm] | 2900 | 2900 | 2900 |
ULT Cooling capacity [W | Btu/h] | 0 | 0 | 0 | 0 | 0 | 0 | |
ULT COP [W/W | Btu/Wh] | 0 | 0 | 0 | 0 | 0 | 0 | |
LBP Cooling capacity [W | Btu/h] | 91 | 312 | 91 | 312 | 91 | 312 | |
LBP COP [W/W | Btu/Wh] | 1.32 | 4.5 | 1.32 | 4.5 | 1.32 | 4.5 | |
MBP Cooling capacity [W | Btu/h] | 0 | 0 | 0 | 0 | 0 | 0 | |
MBP COP [W/W | Btu/Wh] | 0 | 0 | 0 | 0 | 0 | 0 | |
HBP Cooling capacity [W | Btu/h] | 0 | 0 | 0 | 0 | 0 | 0 | |
HBP COP [W/W | Btu/Wh] | 0 | 0 | 0 | 0 | 0 | 0 | |
Approvals | CCC | No | No | No |
EAC | Yes | Yes | No | |
EN 60335-2-34 with Annex AA | Yes | Yes | Yes | |
EN 60335-2-34 | No | No | No | |
UL | No | No | No | |
E4 72/245 95/54 0277 00 | No | No | No | |
IEC 60335-1 & IEC 60335-2-34 | No | No | No | |
Inmetro | No | No | No | |
E4 72/245 95/54 0211 37 | No | No | No | |
CB - IEC 60335-2-34 | No | No | No | |
KC | No | No | No |