Displacement from – to 6.23 - 11.15 cm³ and cover a cooling capacity (ASHRAE) range of:
Variants for FF6GK | variant 1 | variant 2 | |
---|---|---|---|
Code number | 103G5680 | 103G5684 | |
Type designation | FF6GK | FF6GK | |
Product status | Production - Active | Production - Active | |
Performance | Check Performance | Check Performance | |
Data Sheet | Download | ||
3D Model | |||
Power supply | 220-240V/50Hz | No | No |
110-115V/50Hz | No | No | |
115-127V/60Hz | Yes | Yes | |
208-230V/60Hz | No | No | |
12-24V DC | No | No | |
48V DC | No | No | |
Refrigerants | R170 | No | No |
R1270 | No | No | |
R134a | Yes | Yes | |
R513A | No | No | |
R1234yf | No | No | |
R290 | No | No | |
R404A | No | No | |
R452A | No | No | |
R407C | No | No | |
R600a | No | No | |
Applications | LBP | Yes | Yes |
MBP | Yes | Yes | |
HBP | Yes | Yes | |
ULT | No | No | |
Motors | RSIR | Yes | Yes |
RSCR | No | No | |
CSIR | No | No | |
CSCR | No | No | |
DC/PM | No | No | |
Pre-assembled start equipment | No | No | |
Dimensions | Height [mm | in.] | 196 | 7.72 | 196 | 7.72 |
Weight [kg | lbs.] | 10.6 | 23.4 | 10.6 | 23.4 | |
Discharge connector ⌀ [mm | in.] | 6.5 | 0.26 | 6.2 | 0.24 | Discharge Material | Cu-plated steel | Cu-plated steel |
Process connector ⌀ [mm | in.] | 6.5 | 0.26 | 6.2 | 0.24 | |
Process Material | Cu-plated steel | Cu-plated steel | |
Suction connector ⌀ [mm | in.] | 8.2 | 0.32 | 8.2 | 0.32 | |
Suction Material | Cu-plated steel | Cu-plated steel | |
Design | Evap. tray fixture | ||
Displacement [cm³ | cu.in.] | 6.23 | 0.38 | 6.23 | 0.38 | |
Oil Charge [cm³ | fl.oz.] | 400 | 13.53 | 400 | 13.53 | |
Oil Type | POE | POE | |
Performance | Motor Speed [rpm] | 3500 | 3500 |
ULT Cooling capacity [W | Btu/h] | 0 | 0 | 0 | 0 | |
ULT COP [W/W | Btu/Wh] | 0 | 0 | 0 | 0 | |
LBP Cooling capacity [W | Btu/h] | 122 | 417 | 122 | 417 | |
LBP COP [W/W | Btu/Wh] | 0.93 | 3.2 | 0.93 | 3.2 | |
MBP Cooling capacity [W | Btu/h] | 348 | 1188 | 348 | 1188 | |
MBP COP [W/W | Btu/Wh] | 1.59 | 5.4 | 1.59 | 5.4 | |
HBP Cooling capacity [W | Btu/h] | 675 | 2306 | 675 | 2306 | |
HBP COP [W/W | Btu/Wh] | 2.32 | 7.9 | 2.32 | 7.9 | |
Approvals | CCC | No | No |
EAC | No | No | |
EN 60335-2-34 with Annex AA | No | No | |
EN 60335-2-34 | No | No | |
UL | Yes | Yes | |
E4 72/245 95/54 0277 00 | No | No | |
IEC 60335-1 & IEC 60335-2-34 | No | No | |
Inmetro | No | No | |
E4 72/245 95/54 0211 37 | No | No | |
CB - IEC 60335-2-34 | No | No | |
KC | No | No |