Product Details for SC12MLX

  • Secop S-Series Compressors are available in:

    Displacement from – to 10.29 - 20.95 cm³ and cover a cooling capacity (ASHRAE) range of:

    • LBP: 167–1137 W
    • MBP: 493–1868 W
    • HBP: 923–2266 W
    Sales Request Technical Support
Variants for SC12MLX variant 1 variant 2
Code number 104L1606 104L2606
Type designation SC12MLX SC12MLX
Product status Production - Active Production - Active
Performance Check Performance Check Performance
Data Sheet Download Download
3D Model
Power supply 220-240V/50Hz No Yes
110-115V/50Hz No No
115-127V/60Hz Yes No
208-230V/60Hz No Yes
12-24V DC No No
48V DC No No
Refrigerants R170 No No
R1270 No No
R134a No No
R513A No No
R1234yf No No
R290 No No
R404A Yes Yes
R452A No Yes
R407C No No
R600a No No
Applications LBP No No
MBP Yes Yes
HBP No No
ULT No No
Motors RSIR No No
RSCR No No
CSIR Yes Yes
CSCR Yes No
DC/PM No No
Pre-assembled start equipment No No
Dimensions Height [mm | in.] 219 | 8.62 219 | 8.62
Weight [kg | lbs.] 13.8 | 30.4 13 | 28.7
Discharge connector ⌀ [mm | in.] 6.5 | 0.26 6.5 | 0.26
Discharge Material Copper Copper
Process connector ⌀ [mm | in.] 6.5 | 0.26 6.5 | 0.26
Process Material Copper Copper
Suction connector ⌀ [mm | in.] 8.2 | 0.32 8.2 | 0.32
Suction Material Copper Copper
Design Evap. tray fixture
Displacement [cm³ | cu.in.] 12.87 | 0.79 12.87 | 0.79
Oil Charge [cm³ | fl.oz.] 550 | 18.6 550 | 18.6
Oil Type POE POE
Performance Motor Speed [rpm] 3500 2900
ULT Cooling capacity [W | Btu/h] 0 | 0 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0 0 | 0
LBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0
LBP COP [W/W | Btu/Wh] 0 | 0 0 | 0
MBP Cooling capacity [W | Btu/h] 1276 | 4358 1091 | 3724
MBP COP [W/W | Btu/Wh] 1.53 | 5.2 1.57 | 5.4
HBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0
HBP COP [W/W | Btu/Wh] 0 | 0 0 | 0
Approvals CCC No Yes
EAC No Yes
EN 60335-2-34 with Annex AA No No
EN 60335-2-34 No Yes
UL Yes Yes
E4 72/245 95/54 0277 00 No No
IEC 60335-1 & IEC 60335-2-34 No No
Inmetro No No
E4 72/245 95/54 0211 37 No No
CB - IEC 60335-2-34 No No
KC No Yes