Last Update
03.02.2025
Configuration-Code NF7FK16


Code number 105G5728 105G5745
Type designation NF7FK NF7FK
Product status Production - Active Production - Variant
Data Sheet Download Download
Setup
Polynomial NF7FK16
Voltage range [V … V] 95 … 135
Frequency 60
High starting torque yes
Run capacitor no
Motor speed [rpm] 3500
Variable speed no
Refrigerant R134a
Specials Tropical use recommended yes
Heavy duty pull down capability yes
Mobile operation possible no
Hot gas defrost capability no
Cooling Required cooling Max. ambient temp.: 43°C F1 (fan 1.5m/s)
Operation limits diagram = short = continuous
CECOMAF CECOMAF ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 180 | 615 380 | 1298 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 0.93 | 3.2 1.33 | 4.5 n/a | n/a
ASHRAE ASHRAE ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 244 | 833 488 | 1667 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.2 | 4.1 1.61 | 5.5 n/a | n/a
EN12900 EN12900 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 119 | 406 423 | 1445 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 0.98 | 3.3 1.58 | 5.4 n/a | n/a
ARI540 ARI540 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 198 | 676 459 | 1567 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1 | 3.4 1.57 | 5.4 n/a | n/a
AHAM AHAM ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 262 | 895 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.37 | 4.7 n/a | n/a n/a | n/a
VSD_opt1 VSD_opt1 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 242 | 826 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.33 | 4.5 n/a | n/a n/a | n/a
VSD_opt2 VSD_opt2 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 219 | 748 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.2 | 4.1 n/a | n/a n/a | n/a
lowTemp lowTemp ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a n/a | n/a n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a n/a | n/a n/a | n/a n/a | n/a