Configuration-Code TFS45FT16M


Code number 102G3424 102G3426 102G3432
Type designation TFS4.5FT TFS4.5FT TFS4.5FT
Product status Production - Variant Production - Variant Production - Active
Data Sheet Download Download Download
Setup
Polynomial TFS45FT16M
Voltage range [V … V] 95 … 135
Frequency 60
High starting torque yes
Run capacitor no
Motor speed [rpm] 3500
Variable speed no
Refrigerant R134a
Specials Tropical use recommended yes
Heavy duty pull down capability yes
Mobile operation possible no
Hot gas defrost capability no
Cooling Required cooling Max. ambient temp.: 43°C F1 (fan 1.5m/s)
Operation limits diagram = short = continuous
CECOMAF CECOMAF ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 102 | 348 231 | 789 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 0.84 | 2.9 1.27 | 4.3 n/a | n/a
ASHRAE ASHRAE ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 140 | 478 298 | 1018 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.1 | 3.8 1.51 | 5.2 n/a | n/a
EN12900 EN12900 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 82 | 280 259 | 884 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 0.88 | 3 1.47 | 5 n/a | n/a
ARI540 ARI540 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 118 | 403 280 | 956 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 0.93 | 3.2 1.44 | 4.9 n/a | n/a
AHAM AHAM ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 165 | 563 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.32 | 4.5 n/a | n/a n/a | n/a
VSD_opt1 VSD_opt1 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 155 | 529 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.3 | 4.4 n/a | n/a n/a | n/a
VSD_opt2 VSD_opt2 ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a 137 | 468 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.14 | 3.9 n/a | n/a n/a | n/a
lowTemp lowTemp ULT LBP MBP HBP
Cooling capacity [W | Btu/h] n/a | n/a n/a | n/a n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a n/a | n/a n/a | n/a n/a | n/a