Last Update
03.02.2025

Product Details for SC12CNX.2

  • Secop S-Series Compressors are available in:

    Displacement from – to 10.29 - 20.95 cm³ and cover a cooling capacity (ASHRAE) range of:

    • LBP: 167–1137 W
    • MBP: 493–1868 W
    • HBP: 923–2266 W
    Sales Request Technical Support
Variants for SC12CNX.2 variant 1 variant 2 variant 3
Code number 104H7270 104H7271 104H8266
Type designation SC12CNX.2 SC12CNX.2 SC12CNX.2
Product status 製造中 同系統品を製造中 製造中
Performance Check Performance Check Performance Check Performance
Data Sheet Download Download Download
3D Model Download Download
Power supply 220-240V/50Hz No No Yes
110-115V/50Hz No No No
115-127V/60Hz Yes Yes No
208-230V/60Hz No No No
12-24V DC No No No
48V DC No No No
Refrigerants R170 No No No
R1270 No No No
R134a No No No
R513A No No No
R1234yf No No No
R290 Yes Yes Yes
R404A No No No
R452A No No No
R407C No No No
R600a No No No
Applications LBP Yes Yes Yes
MBP Yes Yes No
HBP No No No
ULT No No No
Motors RSIR No No No
RSCR No No No
CSIR Yes Yes Yes
CSCR No No No
DC/PM No No No
Pre-assembled start equipment No Yes No
Dimensions Height [mm | in.] 209 | 8.23 209 | 8.23 209 | 8.23
Weight [kg | lbs.] 13.2 | 29.1 13.2 | 29.1 13.1 | 28.9
Discharge connector ⌀ [mm | in.] 6.5 | 0.26 6.5 | 0.26 6.2 | 0.24
Discharge Material Copper Copper Copper
Process connector ⌀ [mm | in.] 6.5 | 0.26 6.5 | 0.26 6.2 | 0.24
Process Material Copper Copper Copper
Suction connector ⌀ [mm | in.] 9.63 | 0.38 9.63 | 0.38 8.2 | 0.32
Suction Material Copper Copper Copper
Design Evap. tray fixture
Displacement [cm³ | cu.in.] 12.87 | 0.79 12.87 | 0.79 12.87 | 0.79
Oil Charge [cm³ | fl.oz.] 500 | 16.91 500 | 16.91 550 | 18.6
Oil Type POE POE POE
Performance Motor Speed [rpm] 3500 3500 2900
ULT Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0
LBP Cooling capacity [W | Btu/h] 613 | 2093 613 | 2093 491 | 1676
LBP COP [W/W | Btu/Wh] 1.29 | 4.4 1.29 | 4.4 1.2 | 4.1
MBP Cooling capacity [W | Btu/h] 1184 | 4042 1184 | 4042 0 | 0
MBP COP [W/W | Btu/Wh] 1.89 | 6.5 1.89 | 6.5 0 | 0
HBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0
HBP COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0
Approvals CCC No No Yes
EAC No No No
EN 60335-2-34 with Annex AA No No No
EN 60335-2-34 No No Yes
UL Yes Yes No
E4 72/245 95/54 0277 00 No No No
IEC 60335-1 & IEC 60335-2-34 No No No
Inmetro No No No
E4 72/245 95/54 0211 37 No No No
CB - IEC 60335-2-34 No No No
KC No No No