Last Update
03.02.2025

Product Details for TF4CLX

  • Secop T-Series Compressors are available in:

    Displacement from – to 2.6 - 10.13 cm³ and cover a cooling capacity (ASHRAE) range of:

    • LBP: 45–272 W
    • MBP: 11–392 W
    • HBP: 218–488 W
    Sales Request Technical Support
Variants for TF4CLX variant 1 variant 2 variant 3
Code number 102U2102 102U2114 102U2124
Type designation TF4CLX TF4CLX TF4CLX
Product status Production - Active Production - Variant Production - Variant
Performance Check Performance Check Performance Check Performance
Data Sheet Download Download Download
3D Model
Power supply 220-240V/50Hz No No No
110-115V/50Hz No No No
115-127V/60Hz Yes Yes Yes
208-230V/60Hz No No No
12-24V DC No No No
48V DC No No No
Refrigerants R170 No No No
R1270 No No No
R134a No No No
R513A No No No
R1234yf No No No
R290 No No No
R404A Yes Yes Yes
R452A Yes No Yes
R407C No No No
R600a No No No
Applications LBP Yes Yes Yes
MBP Yes Yes Yes
HBP No No No
ULT No No No
Motors RSIR No No No
RSCR No No No
CSIR Yes Yes Yes
CSCR No No No
DC/PM No No No
Pre-assembled start equipment No No Yes
Dimensions Height [mm | in.] 173 | 6.81 173 | 6.81 173 | 6.81
Weight [kg | lbs.] 8.1 | 17.9 8.1 | 17.9 8.1 | 17.9
Discharge connector ⌀ [mm | in.] 5 | 0.2 6.5 | 0.26 5 | 0.2
Discharge Material Copper Copper Copper
Process connector ⌀ [mm | in.] 6.5 | 0.26 6.5 | 0.26 6.5 | 0.26
Process Material Copper Copper Copper
Suction connector ⌀ [mm | in.] 6.5 | 0.26 6.5 | 0.26 6.5 | 0.26
Suction Material Copper Copper Copper
Design Evap. tray fixture
Displacement [cm³ | cu.in.] 3.86 | 0.24 3.86 | 0.24 3.86 | 0.24
Oil Charge [cm³ | fl.oz.] 280 | 9.47 280 | 9.47 280 | 9.47
Oil Type POE POE POE
Performance Motor Speed [rpm] 3500 3500 3500
ULT Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0
LBP Cooling capacity [W | Btu/h] 206 | 704 206 | 704 206 | 704
LBP COP [W/W | Btu/Wh] 1.12 | 3.8 1.12 | 3.8 1.12 | 3.8
MBP Cooling capacity [W | Btu/h] 379 | 1294 379 | 1294 379 | 1294
MBP COP [W/W | Btu/Wh] 1.41 | 4.8 1.41 | 4.8 1.41 | 4.8
HBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0
HBP COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0
Approvals CCC No No No
EAC No No No
EN 60335-2-34 with Annex AA No No No
EN 60335-2-34 No No No
UL Yes Yes Yes
E4 72/245 95/54 0277 00 No No No
IEC 60335-1 & IEC 60335-2-34 No No No
Inmetro No No No
E4 72/245 95/54 0211 37 No No No
CB - IEC 60335-2-34 No No No
KC No No No