Displacement from – to 6.13 - 14.65 cm³ and cover a cooling capacity (ASHRAE) range of:
Variants for NLV8.0CN | variant 1 | variant 2 | variant 3 | |
---|---|---|---|---|
Code number | 105H7808 | 105H7813 | 105H7809 | |
Type designation | NLV8.0CN | NLV8.0CN | NLV8.0CN | |
Product status | Production - Active | Production - Active | Production - Variant | |
Performance | Check Performance | Check Performance | Check Performance | |
Data Sheet | Download | Download | ||
3D Model | Download | Download | Download | |
Power supply | 220-240V/50Hz | Yes | Yes | Yes |
110-115V/50Hz | Yes | No | Yes | |
115-127V/60Hz | Yes | No | Yes | |
208-230V/60Hz | Yes | Yes | Yes | |
12-24V DC | No | No | No | |
48V DC | No | No | No | |
Refrigerants | R170 | No | No | No |
R1270 | No | No | No | |
R134a | No | No | No | |
R513A | No | No | No | |
R1234yf | No | No | No | |
R290 | Yes | Yes | Yes | |
R404A | No | No | No | |
R452A | No | No | No | |
R407C | No | No | No | |
R600a | No | No | No | |
Applications | LBP | Yes | Yes | Yes |
MBP | Yes | Yes | Yes | |
HBP | No | No | No | |
ULT | No | No | No | |
Motors | RSIR | No | No | No |
RSCR | No | No | No | |
CSIR | No | No | No | |
CSCR | No | No | No | |
DC/PM | Yes | Yes | Yes | |
Pre-assembled start equipment | No | No | No | |
Dimensions | Height [mm | in.] | 203 | 7.99 | 203 | 7.99 | 203 | 7.99 |
Weight [kg | lbs.] | 10.8 | 23.8 | 10.8 | 23.8 | 10.8 | 23.8 | |
Discharge connector ⌀ [mm | in.] | 6.2 | 0.24 | 6.2 | 0.24 | 6.5 | 0.26 | Discharge Material | Copper | Copper | Copper |
Process connector ⌀ [mm | in.] | 6.2 | 0.24 | 6.2 | 0.24 | 6.5 | 0.26 | |
Process Material | Copper | Copper | Copper | |
Suction connector ⌀ [mm | in.] | 8.2 | 0.32 | 8.2 | 0.32 | 8.2 | 0.32 | |
Suction Material | Copper | Copper | Copper | |
Design | Evap. tray fixture | |||
Displacement [cm³ | cu.in.] | 7.96 | 0.49 | 7.96 | 0.49 | 7.96 | 0.49 | |
Oil Charge [cm³ | fl.oz.] | 300 | 10.14 | 300 | 10.14 | 300 | 10.14 | |
Oil Type | POE | POE | POE | |
Performance | Motor Speed [rpm] | 2000 | 2000 | 2000 |
ULT Cooling capacity [W | Btu/h] | 0 | 0 | 0 | 0 | 0 | 0 | |
ULT COP [W/W | Btu/Wh] | 0 | 0 | 0 | 0 | 0 | 0 | |
LBP Cooling capacity [W | Btu/h] | 265 | 906 | 272 | 928 | 265 | 906 | |
LBP COP [W/W | Btu/Wh] | 1.73 | 5.9 | 1.84 | 6.3 | 1.73 | 5.9 | |
MBP Cooling capacity [W | Btu/h] | 487 | 1663 | 483 | 1650 | 487 | 1663 | |
MBP COP [W/W | Btu/Wh] | 2.28 | 7.8 | 2.38 | 8.1 | 2.28 | 7.8 | |
HBP Cooling capacity [W | Btu/h] | 0 | 0 | 0 | 0 | 0 | 0 | |
HBP COP [W/W | Btu/Wh] | 0 | 0 | 0 | 0 | 0 | 0 | |
Approvals | CCC | Yes | Yes | Yes |
EAC | No | No | No | |
EN 60335-2-34 with Annex AA | No | No | No | |
EN 60335-2-34 | Yes | No | Yes | |
UL | Yes | No | Yes | |
E4 72/245 95/54 0277 00 | No | No | No | |
IEC 60335-1 & IEC 60335-2-34 | No | No | No | |
Inmetro | No | No | No | |
E4 72/245 95/54 0211 37 | No | No | No | |
CB - IEC 60335-2-34 | Yes | No | Yes | |
KC | No | No | No |